Interpretation ID: aiam1295
Nissan Motor Co.
Ltd.
560 Sylvan Avenue
Englewood Cliffs
NJ 07632;
Dear Mr. Kato: This is in reply to your letter of September 25, 1973, asking whethe the fuel spillage measurement specified in Standard No. 301 is an average rate of one ounce per minute (your Item A) or an actual rate. (Your Item B); Your item B is correct. Fuel spillage shall not exceed one ounce pe minute in any one of the fifteen minutes of the observed period.; Yours truly, Richard B. Dyson, Assistant Chief Counsel